AQ: Voltage transient/inrush current in induction motors

The voltage transient which occurs whenever there is a sudden change in current in an inductive device. Inductors resist a sudden current change.

V=L di/dt

In electric motors this occurs at start up when the contactors close and shut down when the contactors open. Soft starters reduce the start up transient, but not the shutdown transient.

This also occurs with variable frequency drives which switch the current rapidly and repeatedly.

Voltage transients of 2 to 5 times line voltage are common. This is a primary reason for failure of weakened motor insulation systems. Test standards require high voltage Hipot and Impulse testing of insulation systems in order to ensure that a motor can withstand these transients.
Inrush is something we have always had to deal with, especially with motors that are direct on the line start. The inrush can be as high as seven times the nameplate current. The damage created can be minimal if the motor is started up in the morning and them runs all day.

A motor that runs on a There is one situation that creates a huge inductive spike. Take a motor, lets say it is driving a fan, and it is coasting to a stop. The operator decides to push the start button while it is still coasting. It is a misconception that because the motor is already in motion that you will reduce the starting inrush. You will cause more damage to the insulation system by doing this than you could ever imagine.

The inrush current at start-up for a motor is not an inductive spike. In fact, the small inductance in a motor winding is a slight impedance to the inrush (hence the term), though very slight unless it is a high inductance winding.
An inductive spike is the spike that occurs when voltage is quickly switched between windings. The inductance will not allow current to change instantaneously and must go somewhere.
Changing voltages when the motor is moving because the inductance is an energy storage device. If you reverse voltage on a winding in a permanent magnet motor while the motor is active, the voltage on the winding is momentarily doubled, in theory, but the released energy in the winding can cause huge spikes when the back EMF is no longer opposed by the applied voltage, etc.

AQ: Induction motor surge testing

I’d be very careful about surge testing motors in industrial environments. There is specific guidance from IEEE, NEMA and EASA that talks about surge testing being potentially destructive when done on motors in the field. More specifically, motors with unknown insulation conditions. Surge and hi pot testing are geared for shop testing on repaired or new motors. I’d recommend monitoring online impedance imbalance and current imbalance. We’ve seen many case studies where these two parameters were early indicators of stator faults. I agree that offline, phase to phase resistance and inductance can be great indicators of stator faults. The downside of offline testing is the fact the motor has to be shutdown.

We also recommend looking for faults conducive to stator failures. For example, if you have a high restive imbalance on the circuit this can increase heat inside the motor. The increased heat further stresses the insulation system and can lead to bigger insulation or stator failures. If we could have found the small problem, ie. resistance imbalance, then we could have prevented the stator fault.

Stator is a tricky fault zone because faults typically develop so quickly. With a good overall motor testing program you can find the faults that lead to stator issues and get them corrected early.
I was trying to point out that impedance imbalance and current imbalance can act as good indicators for stator issues. It seemed to me that most people in the discussion we’re focusing on offline tests and there wasn’t much mention of online stator testing.

I always think that these discussions are best if they focus on the technical aspects and remain fairly vendor neutral. That’s why I didn’t really bring up any vendors in my post. I think these discussions are a great way for people to gather a great deal of knowledge from a large sample of reliability professionals. I hope more threads like this pop up because I’m always interested in new technology and finding ways to better diagnose motor faults.

AQ: Soft starter settings

Reference voltage adjustment
Reference voltage is the basic condition of the equipment is able to start or not. Reference voltage adjustment requires the electric motor rotates immediately after voltage applied and the load start up. If the motor does not rotate after voltage applied, we should increase the reference voltage setting value; if the motor start speed is too fast, then reduce the reference voltage setting value. Reference voltage adjustment should be repeated for several times until the load starts immediately after voltage applied. For example, a smoke blower has a 110kW motor in debugging process with soft starter, reference voltage adjusts to 75% rated voltage, the starting current is 500A, motor start up fast; reference voltage adjusts to 40% rated voltage, motor start up in slow speed, starting current rise from 200A to 600A smoothly, and current return back after motor start is completed, therefore, it’s fully meet the soft-start requirements.

Starting time adjustment
Motor acceleration torque and starting time has direct relationship. Electronic soft starter can make the motor with voltage ramp start from initial voltage to full voltage at the set time (0.5 to 2408). Like it can reduce water impact if we extend the time of water pump flow from 0 to 100%, increase the pump speed variation time means increase the starting time which can be achieved by adjusting the starting time of the soft starter. Starting time should be adjusted according to the specific loads and repeated tests, in order to achieve smooth acceleration within starting time.

Soft stop
Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the impact of the water pump, when the pump stops suddenly, the water flow inertia in the pipe will raise the pipe and valves pressure suddenly and cause pipeline damaged. Soft stop to extend parking time will solve such the impact.

AQ: Full load torque VS Rated torque

All motors have a “torque vs speed” characteristic.

DC machines are very simple: constant torque from zero speed to some “base speed”, and then a “constant power” ranging from base speed to top speed. In the constant torque range, acceleration is dependent on applied voltage, with the field under constant full current excitation. In the constant power range, voltage is held constant and the field current is reduced, thereby achieving an increase in speed (hence the term “field weakening”).

AC machines are somewhat more complex, since the curves are nowhere near as linear. The key points are:
– “starting torque”, which is the torque achieved at the locked rotor (zero speed) condition
– “pull in torque”, which is the available machine torque at the point where the machine pulls into synchronism (synchronous machines only)
– “pull out or breakdown torque”, which is the peak torque the machine can sustain momentarily before stalling
– “load torque”, which is the amount of torque actually required by the process at any operating point
– “accelerating torque”, which is the difference between what the machine is capable of producing and the load torque

A machine is rated for the “full load torque” condition which is the rated torque performance of the machine. In imperial (lb.ft) units, that would be 5252 * HP / RPM. It can produce this torque continuously, provided it has the rated conditions of applied terminal voltage and applied terminal current (for both rotor and stator, as applicable).

The time required to start a motor is dependent primarily on the accelerating torque available and the combined inertia (motor + remainder of drive train).

Note that available starting and pull-in torque during the transient operation of starting is proportional to the square of the applied voltage – if the voltage dips below 1.0 per unit, the available torque will be significantly reduced.

When operating an AC machine on a

AQ: Choose motors for electric vehicles

My experience with the types of motors in electric vehicle is the following. There are three choices for motors in EVs, permanent magnet PM, integral permanent magnet IPM, and induction motor IM. They each have their pros and cons. A PM has the highest power density; it was used on a military HEV on which I worked. A con for the PM is the back emf during a vehicle run-away. If the vehicle were to go down hill at a high rate of speed a large bemf would be generated that would damage the IGBTs due to excessive DC bus voltage. The integral permanent magnet motor has smaller power density because the magnets are smaller and interior to the rotor, but is a compromise on the excessive bemf during a run away. The IPM has “half” permanent magnet torque and “half” reluctance torque. The IM has the smallest power density, and thus the physically largest for the same power and torque. On the other hand, it does not have an excessive bemf condition during run-away. The IM is also less expensive, but this was not the main consideration on the HEV on which I worked.

The major reason for using PM or IPM motors is power density and efficiency. That results in better mileage, lower weight and additionally less cooling required.
The cost for PM is significantly higher and availability is lower. Especially in Hybrids PM seems to be standard (e.g. Prius) but they have their own motor design.
For run-away the solution Chip suggested is an option. The short circuit currents are not necessary to high for the inverter if the inductance is high enough. That obviously needs a special design for the motor and possibly a short circuit device between motor and drive. Additionally the transients for the short circuit currents can be twice as high as the steady state short circuit currents. Another option would be to disconnect the driveline from the motor mechanically.
Another motor type that has not been discussed here is the high speed switched reluctance motor. Inexpensive to build and high efficiency (although lower power density).

AQ: 3 phase induction motor designs

For 3 phase motor designs, there is hardly any slot combination that will yield a perfectly smooth torque-speed curve. Keeping the following rules in mind will (mostly) avoid the combinations that tend to amplify magnetic noise, harmonics, and parasitic torques.

Let the number of stator slots be S, and the number of rotor slots be R, and the number of poles be P. Undesirable combinations occur when any of the following are true:

1. S – R = 0
2. S – R = +1 OR -1
3. S – R = +2 OR -2
4. S – R = +P or -P
5. S – R = +(P + 1) or -(P +1)
6. S – R = +(P + 2) or -(P + 2)
7. S – R = -(P * 2)
8. S – R = -(P * 5)
9. S – R = +(P * 3) or -(P * 3) .. or multiples of +/-(3 * P).

We know the stator should have an even number of slots to make winding easier – although for certain pole counts, it too can be an odd integer value. And except for a few cases, the number of rotor slots can be either even OR odd.

Then it comes down to the accuracy of the compound die or indexing die for the slot stamping.

AQ: What factors cause Current unbalance

1. Voltage unbalance in supply side (1% volts could easily be 10% current).
2. Physical differences between individual stator coil shapes and connections causing small (but noticeable) resistance changes.
3. Unsymmetrical magnetic circuit – not as big a deal in the smaller “ring” lamination designs, unless highly saturated.
4. Lightly loaded machines will exhibit far higher unbalance than those loaded closer to the full nameplate rating (mostly due to the magnetizing current requirements and associated core/stray loss).

For quick solution measure the current in the three phases, then change the three supply terminals by shift the three terminal to rotate the motor in the same direction, and measure again the current, if the high current move with a certain phase (example: phase L1 of supply read high current in the two case above) the problem is from supply, you can then measure the voltage at motor terminal to be sure that the control circuit and cable are good.

AQ: Electrical machine software

You can categorize the electrical machine software into 2 basic types:

1) FEA packages that may or may not have a front end for analyzing motors. These are available from companies like Vector Field (now Cobham), Infolytica and a few others.
2) Motor design specific software such as the SPEED software, RMxprt and MotorSolve from Infolytica.

In the first category, the FEA packages are expensive because they are general purpose modeling packages. The motor add-on is usually limited mostly to the building the model and perhaps some specialized post-processing for motors. Their main advantages are:

1) 2D and 3D versions.
2) The user is free to define what analysis he wants to perform since they have very advanced general post-processors.

Their main disadvantages are:
1) Cost, they can get very expensive depending on the options you require.In some cases, the motor design module is a cost option.
2) Although they have general post-processors, many users require a lot of training in order to be able to get useful information.
3) Geometry input can be a lot more complicated since the front-ends typically have a limited number of geometries available.

The second category, the motor design software, is specifically designed for motor analysis. It can be magnetic circuit based such as SPEED and RMXprt or full finite element based such as MotorSolve. The magnetic circuit type of software has been available for a long time but it has only been recently that full FEA based motor design packages have become available.

The general advantages of software of this type are:

1) Template based input so the user simply chooses the motor geometry, stator and rotor and sets the parameters for the geometry. The input is therefore very simple but limited to the templates that are implemented in the package.
2) Post-processing is specialized and presented in a form that a motor designer can use it.

The general disadvantages of this type of software is:

1) No specialized post-processing is available directly from these packages unless added by the software provider in a new release.
2) Geometries are limited to the templates and adding templates may be very difficult and has to be done by the software provider.

AQ: Design a PMSM to 10000 rpm high speed

Synchronous speeds are a function of the applied frequency and the number of poles, governed by the equation

120 * (frequency in hertz) / (poles) = (speed in rpm).

Adjust the ratio of frequency to poles to achieve the desired speed.
(example: a 4-pole design would require a line frequency of 333.33 Hz … which means operating on either an adjustable speed drive or on a dedicated high-frequency power system.)

Once you’ve got the electro-magnetics sorted out, it’s a matter of manufacturing to the mechanical constraints associated with the rotational speed.

Well, depending on the power rating, and on the required reliability, I believe it’s very simply. The biggest problem would be to get a variable frequency drive, or other power supply to provide a 3-phase output frequency of about 500Hz.
An automotive alternator should be able to operate relatively reliably at your required speed, and it can probably deliver around 1.5kW at that speed.
In order to make it permanently magnetised, we just have to disassemble the rotor, take the rotor windings out, and replace them with some ring-shaped permanent magnet. We may possibly also use a number of individual smaller permanent magnets embedded in some non-magnetic material such a copper or aluminium between the two half-shelves of the rotor. Depending on the construction of the alternator, we may need some machine shop to pull the rotor halves apart, perhaps machine some material away to make room for the permanent magnet(s), and to press the assembly back together again, and to balance it afterwards.

AQ: Reduce cost of single and three induction motor

First you must optimize the design for the application. This is true for the electromagnetic and mechanical design. If you are making a general purpose motor then this will be more challenging because you will have to compromise to meet a variety of requirements. But the process is the same. You can design by hand using knowledge and experience or, better you can use the numerous design tools, many of which have perimetric design, variable ranges or optimization methods.
To evaluate your designs you need a cost equation. You simply multiply the weight of material and the cost or relative cost of the materials. Can you reduce the amount of the most expensive materials by making better use of the less expensive ones. Often you can.

With a similar approach you can review the mechanical design and you must be aware the these two activities can become intertwined. It is understanding this tight interrelationship that makes a good machine designer. So you must ask are you using the materials effectively? If for example you have poor cooling, optimization of the electromagnetic design will not get you to the lowest cost machine. Don’t forget about fan design, air flow, thermal transfer and similar items. Mechanical also involves the amount of material in the parts. Can the amount of material be reduced and still maintain strength? And so on…

Finally you look at presses. First are your processes themselves reducing the effectiveness of the materials. Poor processes show up in high stray losses, high iron and copper losses. Do you have a good die casting process? What is you vendor doing? Do the know and how can they help you. And sometimes you should ask them how you can help them. If you design is hard to make well, who’s fault is that. Look at winding, excessive material? Insulation, to thick or thin? Do you have good contact between stator and housing?

That is no one thing that gets to a low cost design. It is like playing sports, you have to learn the fundamentals and execute them well. Once you do that, then you can look at automation, more exotic processes and materials. It is a great team project. Pull together someone with sales, electromagnetic, mechanical, and manufacturing process experience and have a go at it. It is great fun and exciting. You will be surprised at what you will find.