{"id":14793,"date":"2023-04-25T14:39:35","date_gmt":"2023-04-25T14:39:35","guid":{"rendered":"http:\/\/iacdrive.com\/?page_id=14793"},"modified":"2024-01-21T01:17:40","modified_gmt":"2024-01-21T01:17:40","slug":"s3300-ce-construction-elevator-control-integrated-inverter","status":"publish","type":"page","link":"http:\/\/abbdrivex.com\/?page_id=14793","title":{"rendered":"S3300 CE CONSTRUCTION ELEVATOR CONTROL INTEGRATED INVERTER"},"content":{"rendered":"\n<p><strong>S3300-CE<\/strong>\u00a0is designed for the construction of load characteristics and control requirements of a specially developed integrated control of a dedicated inverter.<\/p>\n<p>Integrated construction elevator electrical logic, frequency control, brake power, overload protection, increase text display, voice broadcast, floor call, automatic leveling, GPRS function. To meet the energy-saving, low-speed and medium-speed construction lifts in the high-end application requirements.<\/p>\n<p><strong>Specification<\/strong>:<\/p>\n<p><strong>Integrated<\/strong><\/p>\n<p>Integrated electrical logic control, variable frequency control, brake unit, overload protection, brake power, elevator control cabinet to achieve protection and protection functions;<\/p>\n<p><strong>Safe and reliable<\/strong><\/p>\n<p>Lifting special holding brake control;<\/p>\n<p>Pre-excitation and torque verification function, to prevent slip car;<\/p>\n<p>Zero detection, to prevent misuse of the joystick;<\/p>\n<p>Dozens of fault protection, deal with all kinds of unexpected situations;<\/p>\n<p><strong>Dedicated<\/strong><\/p>\n<p>Customized protection design, independent terminal configuration, flexible installation, easy maintenance;<\/p>\n<p>When the load is light, enhance the running speed;<\/p>\n<p>Dedicated phase protection, low-voltage logic control to ensure safe operation of equipment;<\/p>\n<p><strong>Rich to expand<\/strong><\/p>\n<p>Secondary platform development;<\/p>\n<p>With automatic leveling and GPRS functions;<\/p>\n<p><strong>Specification:<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Item<\/strong><\/td>\n<td><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Maximum frequency<\/strong><\/td>\n<td><strong>150 Hz<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Carrier frequency<\/strong><\/td>\n<td><strong>0.5\u201316 kHz, adjusted automatically based on the load features<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>Resolution of input frequency<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 Digital setting: 0.01 Hz<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 Analog setting: maximum frequency x 0.025%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Motor control mode<\/strong><\/td>\n<td><strong>Sensorless vector control (SVC) Voltage\/Frequency (V\/F) control<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Startup torque<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 V\/F: 0.5 Hz, 150%; SVC:0.5 Hz, 200%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Speed range<\/strong><\/td>\n<td><strong>1:100 (SVC)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Speed stability accuracy<\/strong><\/td>\n<td><strong>\u00b10.5% (SVC)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Overload capacity<\/strong><\/td>\n<td><strong>60s for 150% of the rated current, 3s for 180% of the rated current<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>Torque boost<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 Fixed boost<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 Customized boost 0.1%\u201330.0%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>Ramp mode<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 Straight-line ramp<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Basic functions<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 S-curve ramp<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>DC braking<\/strong><\/td>\n<td><strong>DC braking frequency: minimum frequency to rated frequency<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>DC braking current: 0.0% to 120.0% of rated current<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Auto voltage regulation (AVR)<\/strong><\/td>\n<td><strong>It can keep constant output voltage automatically when the mains voltage changes<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Overvoltage\/Overcurrent stall control<\/strong><\/td>\n<td><strong>The current and voltage are limited automatically during the running to avoid frequent overvoltage\/over current tripping<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Rapid current limit<\/strong><\/td>\n<td><strong>It decreases the over current faults to the minimum and ensures normal running of the AC drive<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Torque limit and control<\/strong><\/td>\n<td><strong>It automatically limits torque during running, preventing frequent over current tripping<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Excellent performance<\/strong><\/td>\n<td><strong>It implements control on the asynchronous motor and synchronous motor with the high-performance current vector control technology<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Power dip ride-through<\/strong><\/td>\n<td><strong>It reduces set frequency for load to maintain normal output of the AC drive when the bus voltage remains low, preventing the undervoltage fault during running<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Low voltage protection<\/strong><\/td>\n<td><strong>In the case of sudden bus voltage reduction or power failure, the AC drive stops quickly and restricts the running to prevent hook gliding<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>Overload protection<\/strong><\/td>\n<td><strong>It automatically identifies the load condition, and restricts the hoist running after<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>overload, but allows only the descending running<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"2\"><strong>Three-level function codes<\/strong><\/td>\n<td><strong>The function codes are classified into three levels, respectively for junior, senior,<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>and advanced users<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Display of gearbox use ratio<\/strong><\/td>\n<td><strong>With the internal calculation mode of the gearbox use ratio, the current gearbox use ratio is displayed to users<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Brake time sequence control<\/strong><\/td>\n<td><strong>The time sequence control of a specialized brake for the crane is provided<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Light-load high-speed<\/strong><\/td>\n<td><strong>It detects the output torque of the AC drive and automatically calculates the highest output frequency<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Load overspeed judgment<\/strong><\/td>\n<td><strong>Two alarms indicating frequency direction abnormality and frequency following abnormality based on the encoder feedback frequency are available<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Individualized functions<\/strong><\/td>\n<td><strong>Integrated control<\/strong><\/td>\n<td><strong>Built-in logic for construction hoist simplifies design of control cabinet.<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Multiple fault alarms<\/strong><\/td>\n<td><strong>Probable faults are listed and corresponding solutions are provided<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Advanced background software<\/strong><\/td>\n<td><strong>It supports the AC drive parameter operation and virtual oscilloscope function. By means of the virtual oscilloscope, the state inside the AC drive is monitored<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Static auto-tuning of motor parameters<\/strong><\/td>\n<td><strong>The S3300 supports static auto-tuning of all motor parameters<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Weighing function<\/strong><\/td>\n<td><strong>The S3300 can calculate current load weight according to analog input signal of weighing sensor and supports operation limited due to overload<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td rowspan=\"4\"><strong>Command source<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 Operation panel control<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 Terminal control<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Frequency source<\/strong><\/td>\n<td><strong>Multi-speed<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 5 digital input (DI) terminals, including one that supports up to 100 kHz high- speed pulse input<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Running<\/strong><\/td>\n<td><strong>Input terminal<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 2 analog input (AI) terminals, one supporting only 0\u201310 V voltage input and the other supporting 0\u201310 V voltage input or 4\u201320 mA current input<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 1 high-speed pulse output terminal (open-collector) that supports 0\u2013100 kHz square wave signal output<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 1 digital output (DO) terminal<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Output terminal<\/strong><\/td>\n<td><strong>\u2022\u00a0\u00a0 1 relay output terminal<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td><strong>\u2022\u00a0\u00a0 1 analog output (AO) terminal that supports 0-10 V voltage output or 4\u201320 mA current output<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Display and operation<\/strong><\/td>\n<td><strong>LED display<\/strong><\/td>\n<td><strong>It can display the parameters<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Installation location<\/strong><\/td>\n<td><strong>Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Altitude<\/strong><\/td>\n<td><strong>Lower than 1000 m (derated 1%\/100 m if the altitude is higher than 1000 m)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Ambient temperature<\/strong><\/td>\n<td><strong>\u201310\u00b0C to +40\u00b0C (derated 2%\/degree when between 40\u00b0C and 50\u00b0C)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Humidity<\/strong><\/td>\n<td><strong>Less than 95% RH, without condensing<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Vibration<\/strong><\/td>\n<td><strong>9.8 m\/s2 for below 20 Hz, and 5\\.9 m\/s2 for above 20 Hz<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Environment<\/strong><\/td>\n<td><strong>Storage temperature<\/strong><\/td>\n<td><strong>\u201320\u00b0C to +70\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Pollution level<\/strong><\/td>\n<td><strong>PD2<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>IP level<\/strong><\/td>\n<td><strong>IP20<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Power system<\/strong><\/td>\n<td><strong>IN, TT<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>S3300-CE\u00a0is designed for the construction of load characteristics and control requirements of a specially developed integrated control of a dedicated inverter. Integrated construction elevator electrical logic, frequency control, brake power, overload protection, increase text display, voice broadcast, floor call, automatic leveling, GPRS function. To meet the energy-saving, low-speed and medium-speed construction lifts in the high-end<\/p>\n<div class=\"readmore\"><a class=\"btn slider-btn1\" href=\"http:\/\/abbdrivex.com\/?page_id=14793\">Read More&#8230;<\/a><\/div>\n","protected":false},"author":1,"featured_media":14849,"parent":14765,"menu_order":17,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/pages\/14793"}],"collection":[{"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=14793"}],"version-history":[{"count":2,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/pages\/14793\/revisions"}],"predecessor-version":[{"id":14795,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/pages\/14793\/revisions\/14795"}],"up":[{"embeddable":true,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/pages\/14765"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/abbdrivex.com\/index.php?rest_route=\/wp\/v2\/media\/14849"}],"wp:attachment":[{"href":"http:\/\/abbdrivex.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=14793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}